Reset commands
Issue 4 May 2002
4-3
555-233-123
Reset System 2 (System Cold Start
Without Translations Loading)
All Port circuit packs are reset. All telephone sessions are dropped. Telephones
begin to reconnect to the switch within 30 seconds. In a large system,
reconnection of all telephones may take up to five minutes.
In this restart, all software (Oryx/Pecos, drivers, maintenance, and so forth) is
reset. In addition, the TDM Bus and all port circuit packs are reset.
Typical display
Reset System 3 (System Cold Start
With Translations Loading)
Emergency Transfer is invoked. Translations reload from translation card.
Depending on the translations, the reloading process could take from five to 30
seconds. Thereafter, all port circuit packs are reset, and all telephone sessions
drop. Telephones begin to reconnect to the switch within 30 seconds. In a large
system, reconnection of all telephones may take up to five minutes.
In this restart, all software (Oryx/Pecos, drivers, maintenance, and so forth) is
reset. After the software is reset, all translations load from translation card. In
addition, the TDM Bus and all port circuit packs are reset.
INTERNAL REGISTER TEST
PASSED
LOCAL BUS TEST
PASSED
ROM CHECKSUM TEST
PASSED
CONTROL STATUS TEST
PASSED
DCACHE TEST
PASSED
ICACHE TEST
PASSED
WRITE BUFFER TEST
PASSED
BTO TEST
PASSED
TIMER TEST
PASSED
RESET 2 (COLD_2) PERFORMED
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...