Maintenance Object Repair Procedures
555-233-123
10-950
Issue 4 May 2002
In an FAS Signaling Group, the 24th port of the DS1 Interface circuit pack (for 24
channel interfaces) or the 16th port of the DS1 Interface circuit pack (for 32
channel interfaces) is always the D-channel that carries signaling information for
the other ports (B-channels) on the circuit pack. If a Packet Control circuit pack is
used then only the TN464C or later circuit pack may be used.
In an NFAS Signaling Group, the 24th port of a DS1 Interface circuit pack (for 24
channel interfaces) or the 16th port of a DS1 Interface circuit pack (for 32 channel
interfaces) is administered as a D-channel. The D-channel carries signaling
information for the other ports (B-channels) on that circuit pack. That D-channel
can also carry signaling information for any of the ports on other DS1 Interface
circuit packs in the NFAS Signaling Group. As a result, the 24th port on other
24-channel DS1 Interface circuit packs and the 16th port on other 32-channel DS1
Interface circuit packs can be used as B-channels. A D-channel in an NFAS
Group can signal for B-channels on a total of 20 DS1 Interface circuit packs. This
configuration is known as NFAS Simplex. If a Packet Control circuit pack is used
then only the TN464C or later circuit pack may be used to carry the D-channel,
however other DS1/UDS1 interface circuit packs may be used to carry only
B-channels.
In addition to NFAS Simplex, there is another type of NFAS Group called NFAS
Duplex. This provides the user with more reliability, which is desirable because
NFAS permits the D-channel to signal for so many B-channels. NFAS Duplex
allows the administration of a backup D-channel, which remains in a Standby
state until the Active D-channel goes down. If the Active D-channel does go down,
the backup D-channel takes over and provides signaling for all the B-channels in
the signaling group. In the case that a Packet Control circuit pack is used then
only the TN464C or later may be used to carry the D-channels. B-channels may
be carried by any DS1/UDS1 interfaces.
The ISDN-PRI Signaling Group itself depends on three other entities: the DS1
Interface circuit pack on which the D-channel(s) resides, the ISDN-PRI Signaling
Link Port(s), and the interface link that provides connectivity to the processor
(either the Processor Interface Link or the Packet Control circuit pack). If there are
any problems with the ISDN-PRI Signaling Group, also investigate the ISDN-PRI
Signaling Link Port(s), the DS1 Interface circuit pack(s), and either the Processor
Interface Link or the Packet Control circuit pack.
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...