MAPD-BD (MAPD Interface Circuit Pack TN802)
Issue 4 May 2002
10-1057
555-233-123
n. Error Type 3330: LAN Critical error; critical failure in the Packet Bus
interface to the circuit pack. This failure may be due to an on-board or a
Packet Bus fault.
1. If the Packet Bus is alarmed, refer to the PKT-BUS Maintenance
documentation for recommended repair procedures.
2. If the Packet Bus is not alarmed, clear the alarm and restore the
board to the Packet Bus using the following command sequence:
a. busyout board UUCSS
b. reset board UUCSS
c. test board UUCSS clear
d. release board UUCSS
3. If the problem persists, and there are no PKT-BUS alarms, then
replace the circuit pack. See
‘‘Shutting down NT on the TN802’’
before removing the circuit pack.
o. Error Type 3585 - 3601: the board received misframe errors; the Aux Data
shows the last reported misframe count.
p. Error Type 3840: the circuit pack received a bad control channel message
from the switch. This error is not service-affecting, and requires no action.
The Aux Data describes the following error events:
q. Error Type 3841: the circuit pack detected a transient hardware logic error
(for example, program logic inconsistency). This error resolves when no
faults are detected for 100 minutes. The value in Aux Data field (4358)
indicates the type of hardware problem.
r. Error Type 3842: Bad Translation RAM Location Found error; the call
continues by using another translation location. This error is not
service-affecting and requires no action.
s. Error Type 3843: LAN Receive Parity error; the circuit pack detected an
error in a received frame from the Packet Bus. These errors are most likely
caused by a Packet Bus problem, but may be due to a circuit pack fault.
1. Determine whether the problem is isolated to this circuit pack or if
the problem is caused by Packet Bus faults (see PKT-BUS).
4096
Bad major heading
4097
Bad port number
4098
Bad data
4099
Bad sub-qualifier
4100
State inconsistency
4101
Bad logical link
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...