status station
Issue 4 May 2002
8-385
555-233-123
Field descriptions
status station
This command displays the internal software state information for diagnosis and
to help locate the facilities to which the station is communicating.
Link State
Operational mode of the link:
up
: the link is administered and a call is setup between the switch
and the system printer.
down
: the link is administered, but a call is not setup between the
switch and the system printer.
extension not administered
: the link (no system
printer extension) is not administered
Number of
Retries
Number of times the switch has tried to set up the link since a
request to set up the link was received (1-999); if more than 999
retries have occurred,
999
still displays. (This field displays only if
the
Link State:
field is
down
.)
Maintenance
Busy
Whether any maintenance testing is being performed on the
system printer link:
yes
and
no
: system printer link is administered
blank: system printer link is not administered.
Action/
Object
Qualifier
Qualifier Description
Logins
Defaults
Feature
Interactions
status
station
extension
Station extension (per dial-plan)
Report sent to printer
Examples:
status station 10020
status station 83277
status station 83277 print
init
inads
craft
cust
browse
none
none
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...