MEDPRO (Media Processor MAPD Circuit Pack)
Issue 4 May 2002
10-1073
555-233-123
Control Channel Looparound Test (#52)
This test queries the circuit pack for its circuit pack code and vintage and verifies
its records.
Table 10-399.
TEST #52 Control Channel Looparound Test
Error
Code
Test
Result
Description/Recommendation
None
2100
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
FAIL
The circuit pack failed to return the circuit pack code or vintage.
1. Retry the command a maximum of 5 times.
2. If the problem continues, and if the circuit pack is one
of the Port circuit packs, replace the circuit pack.
Otherwise, if the circuit pack is part of the SPE, use
the procedure described in Replacing SPE Circuit
Packs in Chapter 5.
3. Retry the command a maximum of 5 times.
PASS
Communication with this circuit pack is successful.
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted,
an incorrect board is inserted, or an insane board is inserted.
1. Ensure that the board translations are correct.
Administer the MedPro interface if it is not already
administered.
2. If the board was already administered correctly, check
the error log to determine whether the board is
hyperactive. If this is the case, the board is shut down.
Reseating the board re-initializes the board.
3. If the board was found to be correctly inserted in step
1, then issue the busyout board UUCSS command.
4. Issue the reset board UUCSS command.
5. Issue the release board UUCSS command.
6. Issue the test board UUCSS long command.
This should re-establish the linkage between the internal ID and
the port.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...