Maintenance Object Repair Procedures
555-233-123
10-304
Issue 4 May 2002
50
Requested
Facility Not
Subscribed
Requested facility is implemented, but not
administered. Potential administration problem
with endpoint or adjunct. For BRI endpoints:
1. Verify the switch administration of endpoint
using either the display station or display
data-module commands.
2. If Step 1 does not resolve the problem, refer
to the endpoint’s service manual and verify
administration on the endpoint.
3. If Step 2 does not resolve the problem,
escalate to the next tier.
For ASAI adjuncts:
1. Display the Customer Optional Features
Form (administration screen) on the switch to
determine which ASAI capabilities are turned
on in the switch.
2. Verify that the adjunct is administered to
support the identical capabilities as the
switch. If there is a mismatch in the
administered capabilities, then readminister
the switch and/or the adjunct to establish a
consistent set of desired capabilities on both
the switch and the adjunct.
3. If Step 2 does not resolve the problem,
escalate to the next tier.
For Avaya adjuncts:
1. Display the Customer Optional Features
Form (administration screen) on the switch to
determine if the Avaya adjunct is set enabled
on in the switch.
2. If error type 2567 or 2568, verify the Avaya
adjunct version, and readminister if needed.
3. If step 2 does not fix the problem, escalate to
the next tier of support.
58
Bearer Capability
Not Presently
Available
Requested bearer capability is implemented, but
not administered. No B-channel administered.
See recommendation 50 above.
Service or Option
Not Implemented
Table 10-120.
ISDN-BRI Cause Values — Continued
Code
Explanation
Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...