Maintenance Object Repair Procedures
555-233-123
10-1540
Issue 4 May 2002
■
Cannot reset standby SPE at this time; use the ‘status system’
command
This message is displayed when the standby SPE memory is not
refreshed. Issue the refresh spe-standby command and try the reset
again.
■
Could only hold Standby SPE reset because Active SPE is locked via
SPE select switches
This message is displayed when the refresh spe-standby command is
issued when the active SPE is selected via the SPE select switches.
Because the select switches disable shadowing, the refresh command can
not refresh the memory on the standby SPE. The only effect the refresh
command has is to hold the standby SPE reset.
■
Refresh not successful; use the ‘display errors’ and the ‘dup-spe’
category to check for standby SPE errors
This message line error, which corresponds to Error Codes 2012, 2013,
2014, 2015, 2021, 2024, 2048, 2049, 2050, or 2051, is displayed when a
refresh spe-standby command fails.
■
Standby SPE busy with another task; for information use status
system
This message line error, which corresponds to Error Code 2018, is
displayed if a test command on a Standby SPE component is attempted
while the Active SPE is performing some Maintenance Mode activity on the
Standby SPE other than system technician-demanded maintenance.
1. Issue the refresh spe-standby command to put the Standby SPE
into Standby Mode. This command may have to be issued multiple
times. If the refresh spe-standby command successfully completes
5 times without the Standby SPE becoming labeled “standby” on the
status system form, wait 20 minutes. This does not include cases
where the command completes with the terminal message line
errors “Refresh not successful; use ‘display errors’ to check for
STBY-SPE errors” or “Cannot interrupt Standby SPE while entering
maintenance mode; please try later.” Issue the refresh
spe-standby command once more. If the Standby SPE is not
labeled “standby” on the status system form after this attempt, use
the busyout spe-standby and release spe-standby command to
put the standby into standby mode.
2. Repeat the command.
3. Issue the test spe-standby long command.
■
Standby SPE failed to reset with requested restart level; check for
STBY-SPE errors
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...