XXX-BD (Common Port Circuit Pack)
Issue 4 May 2002
10-2013
555-233-123
Control Channel Loop Around Test (#52)
This test queries the circuit pack for its circuit pack code and vintage and verifies
its records.
SAKI Sanity Test (#53)
This test is destructive.
This test resets the circuit pack.
This test is executed as part of the long test sequence only for the Tone-Clock
circuit pack and DS1 interface circuit packs. All other common circuit packs can
Table 10-723.
TEST #52 Control Channel Loop Around Test
Error
Code
Test Result
Description/Recommendation
none or
2100
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of
5 times.
FAIL
The test failed because the circuit pack failed to return the
circuit pack code or vintage.
1. Retry the command for a maximum of 5 times.
2. If the test still fails, issue the busyout board, reset
board, and release busy board commands, and then
retest.
3. If the problem continues, replace the circuit pack.
4. Run the test again.
PASS
Communication with this circuit pack is successful.
EXTRA BD
This result should only appear for the TN771B or TN771C
Maintenance/Test circuit pack. More than one circuit pack
has been installed in this port network. Remove this circuit
pack.
any
NO BOARD
This is normal if the test is being done when (a) the circuit
pack is not physically in the system or (b) the system is
booting up. Otherwise, there is some inconsistency
between the physical configuration and the data kept in the
system.
1. Verify that the circuit pack is physically in the system.
2. Verify that the system is not in a stage of booting up.
3. ) Retry the command at 1-minute intervals for a
maximum of 5 times.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...