HYB-LINE (Hybrid Line)
Issue 4 May 2002
10-887
555-233-123
This section refers only to the HYB-LINE (Hybrid Line) maintenance that is
performed. Please note that the HYB-LINE (Hybrid Line) maintenance is closely
related to, and interacts with, the HYB-BD (Hybrid Line circuit pack) maintenance
in some instances. Some of the results of maintenance testing of the Hybrid Line
may be affected by the health of the Hybrid Line circuit pack. This interaction
should be kept in mind when investigating the cause of reported Hybrid Line
problems.
There are instances in this section where “service states” of a station are
mentioned. It is helpful to understand what is meant by the different service states
that may exist. An explanation of these service states follows:
■
Out-of-Service–The port, and thus the station, have been removed from
service. A busyout of a port causes it to be out-of-service.
■
Ready-for-Service–Once a port on the circuit pack has been put into
service, the voice terminal must communicate that it is present. The time
between these two events is the time when the terminal is in the
ready-for-service state.
■
In-Service–Once the system has received a message from the voice
terminal communicating that it is present, the station is put into the
in-service state. The terminal can also be forced into the in-service state if
it goes off-hook while it is in the ready-for-service state.
When the status station command has been run, and the status screen appears,
the status is reported as either out-of-service or in-service, which mean exactly as
stated in the above list, or disconnect, which means the station is in the
ready-for-service state.
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...