TBRI-BD (TN2185 ISDN Trunk-Side BRI)
Issue 4 May 2002
10-1657
555-233-123
c. On-board hardware failure. Aux data values correspond to the following
detected errors:
Reset the circuit pack with the busyout board PCSS and reset board
PCSS commands. When reset, the circuit pack executes a set of tests to
detect the presence of any of the faults listed above. Detection of one of
these errors during initialization causes the circuit pack to lock-up and
appear insane to the system. See the repair procedure in Note (a).
d. The circuit pack detects a program logic error. While no action is required,
this error can lead to other errors against this circuit pack.
e. The circuit pack cannot update and read back NPE/NCE memory. This
error can be ignored, but may lead to other errors against this circuit pack.
f. The TN2185 board notifies maintenance software that it has detected a
parity error while accessing its dynamic RAM (that stores the board’s
translation information and downloadable application firmware).
Maintenance software resets the circuit pack.
g. Unable to write LAN Translation RAM Error (internal memory access error).
Translation RAM locations for the call connection attempt are not available,
and one or more RAM locations are bad due to a translation RAM
read-back error. Reset the circuit pack with the busyout board PCSS and
reset board PCSS commands. If the Circuit Pack Restart Test (#594)
passes, then the on-board circuitry is healthy. Retire the alarm with the test
board PCSS long clear command. If the Circuit Pack Restart Test (#594)
fails, replace the circuit pack.
h. Frame overrun at Packet Bus interface. Due to an on-board fault or by
faulty data received on one of the circuit pack’s external ports. If any of the
ports on this circuit pack is alarmed, refer to the repair procedures for those
maintenance objects. If this error persists, maintenance software removes
the board from service; replace the circuit pack.
4352
External RAM error
4353
Internal RAM error
4355
ROM Checksum error
4357
Instruction set error
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...