ATM-BCH (ATM B-Channel Trunk)
Issue 4 May 2002
10-199
555-233-123
i. Error Type 3585: ISDN RESTART message received. Active calls have
been dropped.
The following Aux Data values (Error Type 3585 only) below represent the
trunk’s ISDN call state at the time Error 3585 occurred. This information
can be useful if users report dropped calls on the ISDN-PRI trunks.
j. Error Type 3841: the far-end rejected an ATM CES trunk selected by the
near-end 10 times. The ATM CES trunk may not be administered on the
far-end.
1. Get the physical name of the ATM trunk by noting the decimal
number in the
Aux Data
field.
2. Check administration for the named trunk on the far-end.
3. If problems persist, then busyout the ATM trunk to take it out of the
hunt group.
The WARNING alarm retires automatically whenever a called endpoint
answers an outgoing or incoming call that uses the alarmed trunk.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate problems in the order presented in the table below. When you
clear one of the error codes associated with a given test, you clear errors
generated by other tests in the testing sequence. If you clear errors out of order,
you can lose important information.
Aux
Data
Description
0
An idle trunk received a restart.
10
An ISDN RESTART from the far-end has unexpectedly cleared a
call in the ACTIVE state (call stable, parties talking).
4
7
8
260 263
An ISDN RESTART from the far-end has unexpectedly cleared a
RINGING call.
1
3
6
9
265
An ISDN RESTART from the far-end has unexpectedly cleared a
call before the call entered the RINGING state.
11
12
19
531 267 268
An ISDN RESTART from the far-end has unexpectedly cleared a
call that was already in the process of clearing.
If this condition occurs frequently, the far-end may be trying to
clear trunks that appear to be in the “hung” state.
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...