XXX-BD (Common Port Circuit Pack)
Issue 4 May 2002
10-2009
555-233-123
Table 10-721.
TEST #50 NPE Audit Test
Error
Code
Test Result
Description/Recommendation
none or
2100
ABORT
System resources required for this test are not
available.
1019
ABORT
Test already in progress.
FAIL
Internal System Error.
1. Retry the command at 1-minute intervals a
maximum of 5 times.
PASS
The circuit pack’s NPEs have been updated with their
translation.
EXTRA BD
Certain circuit packs have limitations on how many
circuit packs can be in the system or port network such
as the Maintenance/Test circuit pack (TN771B or
TN771C), the Tone Detector circuit pack (TN748B,
TN748C or TN748D) and the Call Classifier (TN744).
The Maintenance/Test circuit pack allows only one
circuit pack per port network. The Tone Detector and
Call Classifier allow only 10 circuit packs in each
system. All additional circuit packs return EXTRA-BD
and should be removed.
any
NO BOARD
This is normal if the test is being done when (a) the
circuit pack is not physically in the system or (b) the
system is booting up. Otherwise, there is some
inconsistency between the physical configuration and
the data kept in the system.
1. Verify that the circuit pack is physically in the
system.
2. Verify that the system is not in a stage of booting
up.
3. Retry the command at 1-minute intervals for a
maximum of 5 times.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...