CLAN-BD (Control LAN Circuit Pack)
Issue 4 May 2002
10-399
555-233-123
1. Busyout (busyout board UUCSS) and release (release board
UUCSS) circuit pack
2. Allow 30 minutes for condition to clear itself.
3. To re-establish circuit pack into service manually, busyout (busyout
board UUCSS), reset (reset board UUCSS), and release (release
board UUCSS) the circuit pack.
4. If error recurs within 15 minutes, replace the circuit pack.
5. If the same error occurs on a different circuit pack, follow normal
escalation procedures.
r. Error Type 3840: Circuit pack received bad control channel message from
switch.
Aux Data:
s. Error Type 3841-3843: errors do not affect service.
Below, Error Types correspond to descriptions.
These errors do not affect service, however, they may cause reports of
other errors that do affect service.
If Error Type 3843 begins to affect service, it escalates to Error Type 1294.
t. Error Type 3842: Packet interface receive buffers overflowed.
If this error occurs frequently, the overflow may be congesting the circuit
pack.
1. Refer to Receive FIFO Overflow Error Counter Test (#596).
u. Error Type 3844: LAPD frame contains LAPD Protocol Error.
By themselves, these errors do not affect service.
v. Error Type 3845: Angel inter processor error.
By themselves, these errors do not affect service.
4096
Bad major heading
4097
Bad port number
4098
Bad data
4099
Bad sub-qualifier
4100
State inconsistency
4101
Bad logical link
4102
Bad application identifier
3841
Internal firmware error.
3843
Bad translation RAM. Call uses another translation location.
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...