BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI
ISDN-BRI Port)
Issue 4 May 2002
10-277
555-233-123
Table 10-110.
TEST #618 BRI Port Local LAN Loop Around
Error
Code
Test
Result
Description/Recommendation
1015
ABORT
The port is not in the out-of-service service state.
1. Display the BRI Port Status form via the status bri-port
PCSSpp command to determine which stations or
adjuncts are on this port.
2. Use the extension shown on this form in the status
station command to determine if the station or adjunct is
in use.
3. If it is in use, wait until it is idle, and then busyout the port
(using the busyout port PCSSpp command) to place it in
the out-of-service state and repeat this test.
!
WARNING:
Since the “busyout” command is destructive, execution
of this command prior to the port being idle causes all
calls associated with BRI endpoints and all transactions
associated with ASAI or Avaya adjuncts on the port to be
torn down. Note that third party calls established by an
ASAI or Avaya adjunct remain connected even though
the port is taken out-of-service.
1139
ABORT
The Packet Bus in the port network is out-of-service.
1. Follow the repair procedures for the Packet Bus.
2. After completing Step 1, execute the test port long
PCSSpp command, and review the results of the BRI Port
Local LAN Loop Around Test to verify the repair.
1141
ABORT
The PKT-CTRL is out-of-service.
1. Follow the repair procedures for the PKT-CTRL.
2. After completing Step 1, execute the test port long
PCSSpp command, and review the results of the BRI Port
Local LAN Loop Around Test to verify the repair.
1144
ABORT
The PPN Packet Bus is out-of-service.
1. Follow the repair procedures for the Packet Bus.
2. After completing Step 1, execute the test port long
PCSSpp command, and review the results of the BRI Port
Local LAN Loop Around Test to verify the repair.
2012
ABORT
Internal System Error.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...