ADX8D-PT (AUDIX Digital Port)
Issue 4 May 2002
10-23
555-233-123
7
FAIL
Conference Test failed on the primary channel. Some users may
not notice a disruption in service. In extreme cases, the
conferencing feature may not work at all.
14
FAIL
The primary voice channel is not transmitting properly. User
impact may range from no noticeable effect to loss of use of this
port.
15
FAIL
The control channel between the processor and EMBEDDED
AUDIX circuit pack is not transmitting properly. User impact may
range from no noticeable effect to loss of use of this port. This
failure could also be disruptive to other users.
16
FAIL
The secondary voice channel is not transmitting properly. User
impact may range from no noticeable effect to loss of use of this
port.
None
FAIL
The test failed for reasons external to the EMBEDDED AUDIX
circuit pack.
1. Run circuit pack tests to check the Tone Generator circuit
pack and the Tone Detector circuit pack by using the test
board PCSS s command.
2. Resolve any problems that are detected on the Tone
Generator circuit pack or Tone Detector circuit pack.
3. If the Tone Generator and Tone Detector circuit packs are
functioning properly, and if the test still fails, replace the
AUDIX circuit pack (see precaution at the beginning of this
section).
PASS
Voice and Control Channel Local Loop test passed. All channels
are transmitting properly.
1. To be sure that this is not an intermittent problem, repeat this
test up to 10 times and see if it continues to pass.
2. If complaints still exist, examine the connections.
Table 10-9.
TEST #13 Voice and Control Channel Local Loop Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...