BRI-SET, ASAI-ADJ, BRI-DAT
Issue 4 May 2002
10-299
555-233-123
i. This error indicates a problem with Layer 2 over the D-channel between the
switch and the endpoint. When this error occurs, an alarm is raised against
the station or adjunct. Execute the test station <extension> short
command and pay particular attention to the results of the BRI XID Test
(#628). If this test fails, follow the repair procedure for Test #628.
j. This error indicates a problem with the B-channel connection between the
switch and the endpoint. When this error occurs, a warning alarm is raised
against the endpoint. Execute the test station <extension> long
command, and pay particular attention to the results of the BRI Remote
Loop Back Test (#627). If this test fails, follow the repair procedure for Test
#627.
k. This error occurs whenever the point-to-point signaling link to the endpoint
goes down (except when it goes down because either the PKT-CTRL or
the PKT-BUS has failed or has been busied out by system technician).
When this error occurs, an alarm is raised against the endpoint or adjunct.
Execute the test station <extension> short command and pay particular
attention to the results of the Signaling Link Status Test (#626). If this test
fails, follow the repair procedure for Test #626. The alarm is retired when
the signaling link is reestablished to the endpoint or adjunct.
l. Certain ASAI protocol-specific cause codes are logged by switch software.
The cause code can be determined from the following formula:
If the error type is greater than 3712, then the ASAI cause code is equal to
the error type minus 3712. This code was sent to the adjunct by the switch.
If the error type is less than 3712, then the ASAI cause code is equal to the
error type minus 3584. This code was sent to the switch by the adjunct.
A description of the various ASAI cause values is contained in the Table
10-64. This table also contains recommended system technician actions
associated with the cause value. Further information can also be found in
the Avaya ASAI Specification (288-500-03). In addition, the Aux Data field
of the Error Log entry contains additional diagnostic information.
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...