Maintenance Object Repair Procedures
555-233-123
10-1358
Issue 4 May 2002
Table 10-501.
TEST #1275 SCOTCH Synchronous Looparound Test
Error
Code
Test
Result
Description/Recommendation
1000
ABORT
The port is in use or PPP link is connected.
1. Determine when the port is available for testing (status
clan-port UUCSSpp).
2. The port may be forced to the idle state by executing a
busyout port UUCSSpp command.
NOTE:
This command is destructive, causing all calls and links
using the port to be torn down.
1002
ABORT
No TDM bus timeslots available for the test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. Escalate if the problem persists.
1963
ABORT
Firmware indicates that the port is in use or ppp link is connected.
1. Determine when the port is available for testing (status
clan-port UUCSSpp).
2. The port may be forced to the idle state by executing a
busyout port UUCSSpp command.
NOTE:
This command is destructive, causing all calls and links
using the port to be torn down.
2000
ABORT
Did not receive circuit pack test response within the allowable
time period.
1. If this problem persists, reset the circuit pack (busyout
board UUCSS, reset board UUCSS, and release board
UUCSS).
2. If the problem persists, replace the circuit pack.
2012
ABORT
Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...