IPMEDPRO (IP Media Processor Circuit Pack)
Issue 4 May 2002
10-927
555-233-123
IP Address Query Test #1371
This test is destructive.
This test sends the Media processor the IP address, subnet mask, and gateway
translation (IP parameters). If the parameters do not match DEFINITY translation,
the maintenance sub-system reboots the board. The board goes through a
physical board removal and insertion.
When this test fails, it is an indication that an illegal change was made and the
customer should be notified.
Table 10-338.
TEST #1371 IP Address Query Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2100
ABORT
Insufficient system resources to run this test.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2801
ABORT
Unable to find IP address data for this location. Verify that the
board is administered.
2807
ABORT
The board is administered, but not enabled in the change
ip-interfaces form.
FAIL
The IP address, subnet mask, and gateway translation
parameters do not match DEFINITY translations. The board
goes through a physical board removal and insertion.
1. If the problem persists, replace the circuit pack.
PASS
Translation
data
matches.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...