Maintenance Object Repair Procedures
555-233-123
10-1948
Issue 4 May 2002
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate errors in the order they appear in the table below.
Control Channel Loop-Around Test (#52)
This non-destructive test fails if the circuit pack does not return to a sane state
after being reset. This test queries the circuit pack for its code and vintage, and
verifies its records.
Order of Investigation
Short
Test
Sequence
Long Test
Sequence
D/
ND
1
1
D = Destructive; ND = Nondestructive
Control Channel Loop-Around Test #52
X
X
ND
Circuit Pack Restart Test #594
D
Invalid LAPD Frame Error Counter Test #597
X
ND
PPE/LANBIC Receive Parity Error Counter Test
#595
X
ND
Receive FIFO Overflow Error Counter Test #596
X
ND
Packet Interface Test #598
X
X
ND
Congestion Query Test #600
X
X
ND
Link Status Test #601
X
X
ND
Table 10-693.
TEST #52 Control Channel Loop-Around Test
Error
Code
Test
Result
Description/Recommendation
None
2100
ABORT
Could not allocate the necessary system resources to run test.
Retry the command at 1-minute intervals, up to 5 times.
If the problem persists, escalate the problem.
FAIL
The circuit pack failed to return the code or vintage.
Retry command at 1-minute intervals, up to 5 times.
Reset the board (reset board UUCSS).
If reset aborts with error code 1115, busyout (busyout board
UUCSS), reset (reset board UUCSS), and release board
(release board UUCSS).
If test continues to fail, replace the circuit pack.
Escalate the problem if failures continue.
PASS
Test successful.
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...