PR-MAINT (Maintenance Processor [TN2404/TN790
RISC Systems])
Issue 4 May 2002
10-1375
555-233-123
FAIL
MTP reported test failure. The system is not able to reliably
contact INADS with alarm data. However, the system continues
to provide good service.
1. For an internal modem:
a. If MTP Outpulse Relay Test (#102) is also failing, check
for the presence of the INADS trunk, and resolve any
INADS trunk problems.
b. If Test #102 passes, the fault is on the Processor circuit
pack. The circuit pack should be replaced.
2. For an external modem:
a. Check the power to the modem.
b. Check the RS-232 cable connections from the DCE
terminal on the switch to the DTE connector on the
modem. Transmit, Receive, RTS, and CTS signals must
be communicating between the MTP DUART hardware
and the modem hardware
c. The MTP DUART or related circuitry on the processor
circuit pack may have failed. The circuit pack should be
changed at your convenience.
NOTE:
If you replace the Processor circuit pack, you need to
obtain a new license file.
PASS
For an internal modem—MTP detected correct data through the
loop back connection.
For an external modem—The test detected correct data through
the loop back in the MTP DUART hardware ahead of the RS232
connection to the modem, and received a CTS signal from the
external modem.
1. If the system cannot call INADS, or if INADS cannot contact
the system, check with the local Central Office for problems
with the INADS trunk, and verify that the INADS number is
correct.
Table 10-508.
TEST #103 MTP Analog Loop Around Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...