FAIL
No 5 volts power detected from the TN767E circuit pack to the
120A1 CSU Module/T1 Sync Splitter. Problem probably due to an
open fuse on the DS1 board or a faulty ICSU/T1 Sync Splitter.
NOTE Do not swap DS1 boards as this may open the fuse on the
new board.
1. Remove the TN767E from the system and reinsert.
2. Run the test again once the board has finished its reset.
3. If the test continues to fail with this error code, then replace
the CSU Module/T1 Sync Splitter and run the test again.
4. If the test continues to fail with this error code, the problem
could be in the I/O cable between the backplane and the
120A1 CSU Module or the 401A T1 Sync Splitter.
5. If the test continues to fail with this error code, escalate this
problem.
1323
FAIL
A service-affecting CSU Module/T1 Sync Splitter audit failure was
detected by the TN767E DS1 circuit pack. All administered ports
on the DS1 circuit pack are affected and maintenance software
will place the ports into the out-of-service state.
1. Replace the 120A1 CSU Module/T1 Sync Splitter.
1324
FAIL
A non-service-affecting CSU Module/T1 Sync Splitter audit failure
was detected by the TN767E DS1 circuit pack. No ports should
be affected. No immediate action is required. These errors
indicate that the CSU Module/T1 Sync Splitter hardware may
have a problem, and that it should be replaced when practical to
avoid further deterioration.
Table 10-235.
TEST #138 Loss of Signal Alarm Inquiry Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...