Maintenance Object Repair Procedures
555-233-123
10-246
Issue 4 May 2002
1
FAIL
The circuit pack failed to reset
2
FAIL
The circuit pack failed to restart.
Retry command.
If the problem persists, replace the ATM-TRK circuit pack.
PASS
The ATM-TRK circuit pack is successfully reset.
0
NO
BOARD
No board detected.
Check the error log for Error 125 (wrong board) or Error 131 (no
board), and perform the appropriate repair, if needed.
Ensure that the board is properly translated and inserted.
Check for Error 1538 (hyperactivity). If hyperactive, run reset
board UUCSS.
Run the test again. If it fails, replace the ATM-TRK circuit pack,
and retest.
Table 10-98.
ATM Board Reset (#1256) — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...