AN-LN-PT (Analog Line Port)
Issue 4 May 2002
10-131
555-233-123
FAIL
The reflective Looparound Test failed. This could cause noisy
or unreliable connections, or users calling this port may hear
an echo. The problem can also be off-board.
1. Since a line seizure may affect the test, repeat the test at
1-minute intervals for no more than 5 times.
2. Using the test board UUCSS short command, run circuit
pack tests to check the tone generator and the tone
detector circuit packs.
3. Resolve any problems on the tone generator or the tone
detector circuit packs.
4. If the tone generator and tone detector circuit packs are
functioning properly, determine if a voice terminal is
connected and wired properly. Resolve any problems
found.
5. If the test still fails, replace the analog line circuit pack.
PASS
The port provides an analog transmission path to the station
equipment. Investigate user-reported troubles on this port by
running other port tests, by examining station wiring, or by
inspecting the station.
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
This result could be due to incorrect translations, no board is
inserted, an incorrect board is inserted, or an insane board is
inserted.
1. Check to make sure that the board translations are
correct. Use the list configuration command, and resolve
any problems.
2. If the board is correctly inserted, issue the busy board
UUCSS command.
3. Issue the reset board UUCSS command.
4. Issue the release board UUCSS command.
5. Issue the test board UUCSS long command. This
re-establishes the link between the internal ID and the
port.
6. If this is not the case, check to make sure that a valid
board is inserted.
Table 10-43. TEST #161 Looparound Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...