Maintenance Object Repair Procedures
555-233-123
10-940
Issue 4 May 2002
Signaling Link Board Check (#643)
This ISDN-PRI Signaling Link Port D-channel depends on the health of the DS1
Interface circuit pack. This test checks the state of the DS1 Interface circuit pack
transporting the ISDN-PRI Signaling Link Port.
Table 10-344.
TEST #643 Signaling Link Board Check
Error
Code
Test
Result
Description/Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
1700
ABORT
Rollabout video abort. The PRI terminal adapter associated
with this D-channel port is detached from the circuit pack. This
is a normal abort when the rollabout video feature is enabled.
To complete test on this port, either:
1. Re-attach the disconnected PRI terminal adapter and retry
test command, or
2. Disable the rollabout video feature on this circuit pack by
entering change ds1 PCSS and set the “Alarm when PRI
Endpoint Detached field to “y.”
8
FAIL
The DS1 circuit pack is not in-service.
1. Check the Hardware Error Log for entries logged against
DS1-BD and consult the DS1-BD (DS1 Interface Circuit
Pack) Maintenance documentation for repair procedures.
PASS
The DS1 Interface circuit pack transporting the ISDN-PRI
Signaling Link Port is in-service.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...