busyout tdm
Issue 4 May 2002
A-13
555-233-123
busyout tdm
Help Messages
If the system technician presses
HELP
after entering “busyout tdm,” the following
message appears:
Enter TDM bus location: [network(1-3)];carrier(A-B)
Error Messages
If the technician does not enter a port network number followed by bus, the
following message appears:
Identifier invalid
If the port network on which the desired TDM bus resides is unavailable, the
following message appears:
EPN is not available
If the command entered is in conflict with another currently executing command,
then a message appears showing the login id of the conflicting user and the
conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires the
user to restart the command, then the following message appears:
Command resources busy; Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message appears:
All maintenance resources busy; try again later
busyout tone-clock
Help Messages
If the system technician presses
HELP
after entering “busyout tone-clock,” the
following message appears:
Enter tone/clock location: [cabinet(1-3];(carrier(A-E))
Error Messages
If an identifier greater than 3 (three) characters is entered, or the cabinet entered
is not a digit (number), the following message appears:
Identifier invalid
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...