Maintenance Object Repair Procedures
555-233-123
10-522
Issue 4 May 2002
b. This is a software audit error that does not indicate any hardware
malfunction. Run the Short Test Sequence and investigate errors (if any).
c. System Technician has busied out the trunk to out-of-service state. No calls
can be made on this trunk.
d. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
e. DS1 Interface circuit pack detects a hardware error. The Aux Data field
contains the Error Type: 57474, rotary dial rate above 12 pulses per
second; 57473, rotary dial rate below eight pulses per second. Escalate the
error.
f. DS1 Interface circuit pack detects a hardware error. The Aux Data field
contains the Error Type: 57392, no external release on PBX disconnect.
Escalate the error.
g. DS1 Interface circuit pack detects a hardware error. The Aux Data field
contains the Error Type: 57393, belated external release on PBX
disconnect. Escalate the error.
h. DS1 Interface circuit pack is out-of-service. Look for DS1-BD errors in
Hardware Error Log. Refer to the DS1-BD (DS1 Trunk Circuit Pack)
Maintenance documentation for details.
i. Error Type 2305—This error indicates that a signaling change was
detected by the PBX trunk circuit pack which is inconsistent with the
present state of the trunk.
j. Port Audit and Update Test (#36) failed due to an internal system error.
Enter status trunk command to verify the status of the trunk. If the trunk is
out-of-service, then enter the release trunk command to put it back to
in-service. Retry the test command.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order they are presented in the table below when
inspecting errors in the system. By clearing error codes associated with the NPE
Crosstalk Test, for example, you may also clear errors generated from other tests
in the testing sequence.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
1
D = Destructive; ND = Nondestructive
NPE Crosstalk Test (#6)
X
ND
Conference Circuit Test (#7)
X
ND
Port Audit and Update Test (#36)
X
ND
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...