PRI-CDR/SEC-CDR (PRI-CDR Link)
Issue 4 May 2002
10-1415
555-233-123
Link Retry Test (#215)
This test sends a message to the CDR software process to make a data call to the
extension where the CDR output device connects to or opens the EIA port to the
CDR output device. If the CDR link is already up, this test is passed without
making any data call or opening the EIA port.
Table 10-530.
TEST #215 Link Retry Test
Error
Code
Test
Result
Description/Recommendation
10
ABORT
Internal system error
20
ABORT
Internal system error. Internal error in Maintenance Action
Process (MAP). MAP returns an error back to maintenance script
(HMM). Timer expires while waiting for the reply from MAP.
1. Retry the command at 1-minute intervals a maximum of 5
times.
30
ABORT
Internal system error
1. Refer to
‘‘Procedures for Restoring the CDR Link’’
.
1010
ABORT
The CDR link has been busied out to out-of-service.
1. Enter release cdr-link primary|secondary command to
release the CDR link from busyout state.
2. Retry test cdr-link primary|secondary long command to
execute the test.
FAIL
The CDR link CANNOT be established.
1. Refer to the
‘‘Procedures for Restoring the CDR Link’’
for
instructions.
PASS
The CDR link is up.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...