BRI-SET, ASAI-ADJ, BRI-DAT
Issue 4 May 2002
10-293
555-233-123
!
WARNING:
If a significant Packet Bus failure occurs, errors and alarms may not be
logged as expected for BRI-SET/BRI-DAT/ASAI-ADJ/ATT-ADJ/
LGATE-AJ/ATTE-AJ. Conditions under which this occurs are detailed in the
“”Maintenance of the Packet Bus” section of Chapter 9, “Packet Bus Fault
Isolation and Correction”.
The TN2208 ESAI MFB provides DEFINITY with an Ethernet interface to
Adjunct-Switch Application Interface (ASAI) and Avaya adjuncts (for example,
CONVERSANT
®
Voice System). This circuit pack contains 8 ports of line circuit
interface, each of which operates with two B-channels (referred to as B1 and B2
throughout this section) and one D-channel as specified in the Avaya ISDN-BRI
Specification. In this context, the term ‘ ‘ ISDN-BRI port’’ is used to refer collectively
to ports on the TN2208 MFB circuit pack which is connected to ASAI or Avaya
adjuncts. The TN2208 ESAI MFB is handled by switch software as it is an ISDN
BRI compatible board and all maintenance actions referring to ASAI and Avaya
Adjunct Links in this section apply.
In G3iV1.1-286 and G3iV2-386, two types of ISDN-BRI endpoints may be
connected to ISDN-BRI (ISDN Basic Rate Interface Line) TN556 and TN2198
circuit packs: ISDN-BRI station endpoints, ASAI (Adjunct-Switch Application
Interface) and Avaya adjuncts (for example CONVERSANT
®
Voice System).
These circuit packs contain 12 ports of line circuit interfaces, each of which
operates at 192 kilobits per second (kbps) with two B-channels and one
D-channel as specified in the Avaya ISDN-BRI specification (PUB 801-802-100).
For BRI endpoints, each B-channel may support voice or circuit-switched data
and may be circuit-switched simultaneously. The B-channels are not used by
ASAI or Avaya adjuncts. The D-channel is used for conveying signaling between
the switch and a BRI endpoint(s) or ASAI or Avaya adjuncts. Each ISDN-BRI
D-channel is connected to the switch processor and the ISDN-BRI port through
the PKT-CTRL (Packet Control) and the PKT-BUS (Packet Bus).
ISDN-BRI endpoints come in a number of configurations. All endpoints require the
D-channel to convey signaling information to the switch. A voice-only set requires
only one B-channel. A voice and data-capable set requires both B-channels (one
for voice and one for data). Therefore, each TN556 port can support either two
voice-only sets or one voice and data-capable set. Only a single ASAI or Avaya
adjunct may be connected to an ISDN-BRI port. Multiple adjuncts per line are not
supported.
illustrates the physical connection (solid line)
between an ISDN-BRI Circuit Pack and a voice or voice/data set. Each physical
connection allows for two B-channels, as stated above, plus one D-channel. Each
ISDN-BRI circuit pack can support up to 12 of these PHYSICAL connections to
different voice and voice/data sets or ASAI and Avaya adjuncts.
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...