Maintenance Object Repair Procedures
555-233-123
10-250
Issue 4 May 2002
Table 10-102.
ATM Board Framer Looparound Test (#1260)
Error
Code
Test
Result
Description/Recommendation
1002
ABORT
Time slots could not be allocated. Traffic could be heavy or time
slots could be out-of-service.
Run display errors, and perform repairs associated with
TDM-BUS errors.
Retry the command up to 3 times at 1-minute intervals.
1003
ABORT
Tone receiver could not be allocated.
Run display errors, and perform the repairs associated with
TTR-LEV and TONE-PT errors.
The test cannot run unless there is at least one Tone Detector
available on the network that holds the ATM-TRK circuit pack.
Retry the command up to 3 times at 1-minute intervals.
1015
ABORT
ATM-TRK circuit pack not busied out
Busyout the ATM circuit pack.
Rerun the command.
1033
ABORT
ATM-TRK circuit pack not found
See if the switch can see the circuit pack. Run status Trunk
Group.
Retry the command.
1139
ABORT
Major alarm on the EPN packet bus
Run display alarms, and perform the repairs associated with
PKT-BUS errors.
Run display errors, and perform the repairs associated with
PKT-BUS errors.
Retry the command.
1141
ABORT
Packet-interface circuit pack out of service
See PKT-INT (Packet Interface Circuit Pack).
1144
ABORT
Major alarm on the PPN packet bus
Run display alarms, and perform the repairs associated with
PKT-BUS.
Run display errors, and perform the repairs associated with
PKT-BUS.
Retry the command.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...