TBRI-TRK (TN2185 ISDN Trunk-Side BRI)
Issue 4 May 2002
10-1693
555-233-123
Asynchronous Commands
NOTE:
Only one trunk can be tested in a given port network, until the test call is
canceled or completes.
Table 10-624.
TEST #258 ISDN TEST Call
Error
Code
Test
Result
Description/Recommendation
4
ABORT
There is a problem with the Processor Interface Link.
1. Refer to the PI-LINK (Processor Interface Link)
Maintenance documentation.
1004
ABORT
B channel in use.
1. Determine if a call is active on this ISDN Trunk-side BRI
trunk via the status trunk command.
2. When the service state indicates in-service/idle, retry the
test.
1005
ABORT
Bad Configuration (that is, no Maintenance/Test circuit pack)
Issue the test trunk <trunk Group/trunk member>
command and make sure there is a DATA-CHL (NETCON
channel) administered.
1018
ABORT
Test call is disabled.
1. Enable Maintenance on the Trunk Group form.
1024
ABORT
(M/T-DIG) Maintenance/Test Digital Port in use.
1. Wait until yellow and green LEDs are turned off on the
M/T-BD (Maintenance/Test circuit pack).
2. Retry the test. If problem persists, refer to M/T-DIG
(Maintenance/Test Digital Port) documentation.
1113
ABORT
The signaling link has failed; the system cannot send any
messages on behalf of this trunk.
1. Check the results of Test #1251 (Signaling Link State
Check Test).
1114
ABORT
The signaling link is in a transitional state.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...