Maintenance Object Repair Procedures
555-233-123
10-1584
Issue 4 May 2002
Switch Control Destructive EPN Maintenance
Board Interface Test (#325)
This test is destructive.
This test writes test patterns into the EPN Maintenance circuit pack interface and
verifies that it can read back these test patterns successfully. Messages to or from
the EPN Maintenance circuit pack can be lost when this test is run.
ABORT
Refer to STBY-SPE for a description of these error codes.
any
FAIL
This failure indicates that communications with the
Maintenance circuit pack in the EPN is probably not possible.
The EPN Manager I may not be usable.
1. Run the Short Test Sequence several times to make sure
the error is occurring consistently, run the Long Test
Sequence to reset the Switch Control. Sometimes
running the Long Test Sequence may clear the problem.
Remember the Long Test Sequence is destructive.
Placing and receiving calls is affected for several
seconds.
2. Replace the NetPkt or Netcon circuit pack whenever it is
convenient for the customer (unduplicated system) or
right away (High or Critical Reliability system).
PASS
The EPN Maintenance circuit pack interface between the
processor and the Switch Control is working correctly. Test
#325 is a more thorough test of this interface but it is
destructive.
Table 10-586.
TEST #324 Switch Control EPN Maintenance Board Interface Test
— Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...