TBRI-PT (TN2185 ISDN Trunk-Side BRI Port)
Issue 4 May 2002
10-1683
555-233-123
Layer 3 Query Test (#1243)
This test is nondestructive.
This test is used to check the application layer communications across the
in-service ISDN D-Channel. The test passes if a status enquiry message is
successfully sent, fails if the signaling link is down, and aborts if a query is already
running or there is an internal error.
Table 10-619.
TEST #1243 Layer 3 Query
Error
Code
Test
Result
Description/Recommendation
1019
ABORT
Test is already running.
1113
ABORT
The signaling link is down.
1. Use the test port PCSSpp long command to clear any
errors which prevent establishment of the signaling link.
2. Examine the results of Test #626, which is executed with
the command. If this test aborts or fails, follow the repair
procedure for the Signaling Link Status Test.
3. Escalate problem if BRI Layer 3 Query Test continues to
abort.
1139
ABORT
The Packet Bus in the port network is out-of-service.
1. Follow the repair procedures for the Packet Bus.
2. After completing Step 1, execute the test port long
PCSSpp command and review the results of the BRI Port
Local LAN Looparound Test to verify the repair.
1141
ABORT
The PKT-CTRL is out-of-service.
1. Consult the repair procedure for PKT-CTRL.
2. If Step 1 does not resolve the problem, escalate to the
next tier.
1144
ABORT
The PPN Packet Bus is out-of-service.
1. Follow the repair procedures for the Packet Bus in the
PPN.
2. After completing Step 1, execute the test port long
PCSSpp command and review the results of the BRI Port
Local LAN Looparound Test to verify the repair.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...