Maintenance Object Repair Procedures
555-233-123
10-1078
Issue 4 May 2002
NT Reset Test (#1381)
This test is destructive.
This test resets the circuit pack. The test is highly destructive and can only be
initiated by a system technician-demanded reset board UUCSS command.
2100
ABORT
The necessary system resources to execute the test could not
be allocated.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2500
ABORT
Internal system error.
1. Retry the command at 1-minute intervals a maximum
of 3 times.
2801
ABORT
No IP address defined. Verify IP Interfaces translations and
retest.
2802
ABORT
Different IP address pinged than software had allocated for the
test.
1. Retry the command at 1-minute intervals a maximum
of 3 times.
2805
FAIL
The number of pings received did not match the number sent
(normally one ping sent). This means that no ping responses
were received from the gateway defined on the ip-interfaces
form for the Media Processor.
1. Retry the command at 1-minute intervals a maximum
of 3 times.
2807
ABORT
The board is administered, but not enabled in the change
ip-interfaces form.
7, 89,
1007
FAIL
Ping to the destination failed through this port due to the
destination down.
1. Verify that at least one destination reachable through
this port is up.
2. Once verified, execute test port UUCSSpp command
to verify that the H.323 Signaling Group Ping Test
(#1387) passes.
PASS
Ping through this port successful.
Table 10-402.
TEST #1379 Ping Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...