b. The port field in the error log contains the signaling group number for
TSC-ADM errors.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the following tables when
inspecting errors in the system. By clearing error codes associated with the TSC
Heartbeat Inquiry Test, for example, you may also clear errors generated from
other tests in the testing sequence.
TSC Heartbeat Inquiry Test(#604)
This test can be invoked by system technician personnel for any ADMTSC
administered in the switch. The following table indicates the possible error
conditions that might be encountered when the test is invoked. Most of the error
conditions do not log an error, but switched services may take some type of
recovery action in certain instances.
This test sends a USER INFORMATION TSC heartbeat message inquiry across
an Administered TSC to determine if the far-end can respond to a USER
INFORMATION TSC heartbeat message.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
1
D = Destructive; ND = Nondestructive
TSC Heartbeat Inquiry Test (#604)
ND
Table 10-663.
TEST #604 TSC Heartbeat Inquiry Test
Error
Code
Test
Result
Description/Recommendation
2100
ABORT
Could not allocate the necessary system resources to run this
test.
1. Reissue the test tsc-administered command at
1-minute intervals a maximum of 5 times.
1005
ABORT
The Administered TSC does not exist.
1. Display the administration for the Administered TSC.
2. If an Administered TSC is exists, reissue the test
tsc-administered command.
3. If the test continues to abort, escalate problem.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...