Maintenance Object Repair Procedures
555-233-123
10-128
Issue 4 May 2002
FAIL
The terminal equipment is not connected to the circuit pack.
Some terminal equipment, such as modems, may fail even
when connected properly.
1. Remotely test the terminal equipment.
2. If the test fails again, resolve any RING-GEN errors in the
error log, if present.
3. Check all of the wiring between the station equipment
and the switch. Then, run the test again.
4. If the test still fails, the terminal equipment may be
defective. Check and replace it, if necessary.
5. Some terminal equipment might fail even when it is
connected properly. If this is the case, disable the test
using the change station extension command (enter n
into the
Test
field). Note that this action also disables
Tests 6, 7, 35, and 161 on this port.
PASS
The station is connected properly to the switch. Investigate
user-reported troubles on this port by running other port tests,
by examining station wiring, or by inspecting the station.
NOTE:
This test may also pass if no terminal equipment is
connected and the terminal is located very far from the
switch.
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
This result could be due to incorrect translations, no board is
inserted, an incorrect board is inserted, or an insane board is
inserted.
1. Check to make sure that the board translations are
correct. Use the list configuration command, and
resolve any problems.
2. If the board is correctly inserted, issue the busy board
UUCSS command.
3. Issue the reset board UUCSS command.
4. Issue the release board UUCSS command.
5. Issue the test board UUCSS long command. This
re-establishes the link between the internal ID and the
port.
6. If this is not the case, check to make sure that a valid
board is inserted.
Table 10-42.
TEST #48 Station Present Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...