TIE-TRK (Tie Trunk)
Issue 4 May 2002
10-1763
555-233-123
1004
ABORT
(Non-TN497 circuit packs only) The port was seized by a valid
call during the test. The test has been aborted. Use display
trunk xx to determine the trunk group/member number of the
port. Use status trunk to determine the service state of the
port. If the service state indicates that the port is in use, the
port is unavailable for certain tests. (Refer to “Status
Commands” section in
Chapter 8, ‘‘Maintenance Commands
for a full description of all possible
states.) You must wait until the port is idle before retesting.
2000
ABORT
Response to the test request was not received within the
allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this
test. This could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Any
FAIL
This test can fail due to on-board or off-board problems.
Off-board problems of concern include EXP-INTF faults,
TDM-BUS faults, and faults associated with the tone
detectors/tone generators. Clear all off-board problems before
replacing the board. Keep in mind that a TDM-BUS problem is
usually the result of a faulty board connected to the backplane
or bent pins on the backplane.
1. Look for EXP-INTF errors in the error log. If present, refer
to the EXP-INTF Maintenance documentation.
2. Look for TDM-BUS errors in the error log. If present, refer
to the TDM-BUS Maintenance documentation.
3. Look for TONE-BD and/or TONE-PT errors in the error
log. If present, refer to the TONE-BD Maintenance
documentation and the TONE-PT Maintenance
documentation.
4. Test the board when the faults from steps 1, 2, and 3 are
cleared. Replace the board only if the test fails.
Table 10-647.
TEST #6 NPE Crosstalk Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...