Maintenance Object Repair Procedures
555-233-123
10-1448
Issue 4 May 2002
Status of Parameter Downloads
The status station and status attendant screens display the current download
status of individual 84xx, 603, and 301B1 terminals in the
Download Status
field. The possible download states are:
Possible reasons for no terminal download include:
■
Terminal is off-hook
■
Terminal detected a bad checksum
■
Terminal detected a bad or missing EEPROM (refer to hardware error log)
■
Terminal is busy programming data from a previous PROGRAM message
■
Terminal is in the Programming Disabled state
■
Terminal is in the Local Program Options Mode
■
Terminal is disconnected or out of service (use status station command)
Status
Terminal Download State
Complete
The terminal successfully downloaded sometime in the past.
Pending
The system is waiting to download the terminal. This may require
the execution of a background periodic test which could take more
than an hour. A demand download as described above may also be
used to initiate an immediate download.
Not Applicable
Not a programmable terminal.
Table 10-549.
Digital Line Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
0
Any
Any
Any
test port UUCSSpp sh r 1
1 (a)
1 to 20,
40987
None
WARNING
OFF
18 (b)
0
busyout port
UUCSSpp
WARNING
OFF
re port UUCSSpp
257 (c)
40971
None
513 (d)
0
Station (Digital)
Audits Test (#17)
WARNING
OFF
test port UUCSSpp sh r 6
767 (e)
40964
None
WARNING
OFF
769 (f)
40963
40988
None
WARNING
OFF
1025 (g)
None
WARNING
OFF
1281
Any
Station (Digital)
Audits Test (#17)
WARNING
OFF
test port UUCSSpp sh r 4
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...