Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-426
Issue 4 May 2002
test customer-alarm
This command performs hardware diagnostic tests on the leads of the Processor
and EPN maintenance circuit packs, used for customer-provided alarms by
closing the appropriate relay for 1 minute. Failure is verified by checking the
customer alarm attached to the specified circuit pack.
Defaults
The default cabinet is cabinet 1. The default carrier is carrier “a,” except for SPE
duplex system PPNs. In this case the carrier has no default and either “a” or “b”
must be entered. The default for the remaining parameter is a repeat of 1.
Action/
Object
Qualifier
Qualifier Description
Logins
Defaults
Feature
Interactions
test
customer
-alarm
location
short
long
repeat
number
clear
schedule
Extension of the data module or data
channel to be tested (per dial-plan)
Runs test number 115
Runs test number 115 (same as short test
option)
How many times each test in the sequence
is repeated (1-100)
This option causes the test sequence (short
or long) to repeat until the alarm (if any) is
cleared or a single test in the sequence
fails.
1
Command is validated and then a
scheduling form displays to schedule
execution of the command. The command is
then placed in the command queue and is
executed at the specified time. The
information displayed by the command is
sent to the system printer instead of the
screen.
2
Examples:
test customer-alarm
test customer-alarm schedule
test customer-alarm 02 r 2
test customer-alarm 01b r 25
test customer-alarm 01b r 25 schedule
test customer-alarm 2a
test customer-alarm 2a sh
test customer-alarm 01b l schedule
test customer-alarm 3 c
1
If no alarms are registered against the maintenance object then the test sequence is run only once. The long
clear option forces a clear of all alarms if no errors are encountered during testing. The short clear option only
clears alarms pertinent to tests in the short sequence.
2
Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
See
below
none
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...