PPP-PT (Control LAN Packet/Port)
Issue 4 May 2002
10-1363
555-233-123
1
FAIL
System software indicates at least one PPP link session is
down (SOME UP).
1. Isolate downed sessions (status port UUCSSpp or status
link n).
Follow actions based on session information.
2
FAIL
System software indicates all PPP sessions are down (ALL
DOWN).
1. Test the port (test port UUCSSpp) to verify the SCOTCH
Synchronous Looparound Test (#1275) result.
2. If test passes, wait for system software to indicate ALL UP.
3. If the test fails, check the destination and other components
in the path.
4. If the destination and other components in the path are
in-service, take action based on session information.
PASS
All sessions up.
Table 10-503.
TEST #1286 Session Status Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...