CO-TRK (CO Trunk)
Issue 4 May 2002
10-443
555-233-123
Notes:
1. At the administration terminal, busyout the affected port, and run a Long
Test Sequence. Observe the test results. If any tests fail, refer to the
description of the tests and the associated error codes. Release the port. If
users continue to report troubles, check for other errors and make test calls
to determine whether the problem should be escalated or referred to the
CO.
2. At the administration terminal, busyout the affected port, and run a Long
Test Sequence. If Dial Tone Test #0 passes, ignore this error. Release the
port.
2817
57360
Ground but no ringing. This error occurs on
an incoming call on a ground-start trunk. If
ringing is not detected within 5 seconds of
the Tip being grounded, the call is still
accepted. If the CO is of the No. 5ESS.
switch type, ringing delays of more than 5
seconds during heavy traffic are fairly
common.
Check for other errors.
2817
57393
On the TN465, the loop is opening too slowly
after a disconnect. This error indicates an
on-board problem, although the trunk may be
functional. On the TN2138, CO released the
trunk at least 4 minutes after the PBX
dropped the call. This error code is log-only
and causes no other testing to occur. No
alarm is generated.
Check for other errors.
3073
57376
No loop current on incoming call. The
incoming destination has already answered
and no loop current has been detected. If this
is a hard fault, the dial tone test and all
outgoing calls should also fail.
Check for other errors.
3329
57408
Trunk error. No Tip ground detected on
outgoing call. This error occurs when an
attempt is made to seize a ground-start CO
trunk for an outgoing call and Tip ground is
not detected or the caller hangs up before
Tip ground is detected.
See Notes 1 and 2 at end of
table.
3585
57424
No loop current on outgoing call. This error
occurs on attempt to seize a loop or
ground-start trunk for an outgoing call. An
error occurs if loop current is not detected or
the caller hangs up before it is detected.
See Note 3 at end of table.
Table 10-164.
CO Trunk Errors with NO Tests — Continued
Error
Type
Aux
Data
Description and System Action
System Technician Action
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...