Maintenance Object Repair Procedures
555-233-123
10-242
Issue 4 May 2002
Control Channel Loop Test (#52)
The nondestructive Control Channel Loop Test is part of the maintenance
subsystem’s Common Port Board Testing feature. The Common Port Board test
sends board vintage queries to a port circuit pack and checks the responses.
CCMS downlink notifications tell the circuit pack which TDM Bus (A or B) carries
the control channel and which carries the touch tones.
The test passes if the port circuit pack responds. The test aborts if the circuit pack
does not respond. The test fails otherwise.
Table 10-95.
TEST #50 Connection Audit Test
Error
Code
Test
Result
Description/Recommendation
None
2100
ABORT
System resources required for this test are not available.
Retry the command up to 5 times at 1-minute intervals.
1019
ABORT
The test aborted because a test was already running on the port.
Retry the command up to 5 times at 1-minute intervals.
FAIL
Internal system error
Retry the command up to 5 times at 1-minute intervals.
PASS
The circuit pack has been updated with its translation.
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted,
an incorrect board is inserted, or an insane board is inserted.
Check the board translations.
If the ATM-TRK circuit pack is not administered, run add atm
trunk UUCSS.
If the ATM-TRK circuit pack is administered correctly, check the
error log.
If ATM-TRK circuit pack is hyperactive, shut down, and reseat
the circuit pack to force re-initialization.
If the ATM-TRK circuit pack is correctly inserted, run busyout
board.
Run reset board.
Run release busy board.
Run test board long to re-establish the linkage between the
internal ID and the port.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...