FAIL
The test failed because the UDS1 interface circuit pack and the
remote DS1 endpoint are not synchronized to the same clock
rate. The UDS1 interface circuit pack detected a slip alarm. The
error code equals the number of slips detected by the UDS1
interface circuit pack since the last slip alarm inquiry test.
If the UDS1 connects to a T1 network facility or to another switch,
do the following:
1. Retry the command at 1-minute intervals for a maximum of 5
times.
2. If the DS1 interface circuit pack is a TN464C, enter the list
measurement ds1-log UUCSS command to read the error
seconds measurement.
3. Verify that both endpoints of the DS1 link are administered
using the same signaling mode, framing mode, and line
coding.
4. Check the active alarm and error logs for recent alarms and
errors against the synchronization (SYNC). Follow the
suggested repair procedure for these errors.
5. Contact T1 Network Service or the technician at the remote
switch to diagnose the remote DS1 endpoint.
6. Check the physical connectivity of the UDS1 interface circuit
packs and the cable.
7. Replace the local UDS1 interface circuit pack, and repeat the
test.
Table 10-679.
TEST #144 Slip Alarm Inquiry Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...