Reaction Module (REACM)
MPC5644A Microcontroller Reference Manual, Rev. 6
Freescale Semiconductor
733
Figure 23-32. Open circuit detection using hold-off timer
describes how the Hold-off timer detects a short circuit. The Hold-off timer is loaded with
MIN_PWD value and enabled. The condition that indicates that a short circuit occurred is the Hold-off
timer still running and LOD is loaded to the channel output pins. That means the PWM pulse are too
narrow and a short circuit have occurred. In this case the SCDF flag is set in the CHSR, Channel Status
register, of the corresponding channel.
.
Figure 23-33. Short circuit detection using hold-off timer
B - open circuit
wide pulse
current cannot achieve
predefined limit
load hdo timer with MIN_PWD
load hdo with RANGE_PWD
hdo timeout
indicating error
Set OCDR in the status register to indicate
short circuit
C - short circuit
narrow pulse
current passed
predefined limit
load hdo timer with MIN_PWD
timeout occurred in hdo
transition detected in the PWM pulse
SCDR bit is set in the status register
an interrupt is generated if enabled
Summary of Contents for MPC5644A
Page 2: ...MPC5644A Microcontroller Reference Manual Rev 6 2 Freescale Semiconductor...
Page 24: ...MPC5644A Microcontroller Reference Manual Rev 6 24 Freescale Semiconductor...
Page 26: ...MPC5644A Microcontroller Reference Manual Rev 6 26 Freescale Semiconductor...
Page 52: ...Introduction MPC5644A Microcontroller Reference Manual Rev 6 52 Freescale Semiconductor...
Page 56: ...Memory Map MPC5644A Microcontroller Reference Manual Rev 6 56 Freescale Semiconductor...
Page 1228: ...Decimation Filter MPC5644A Microcontroller Reference Manual Rev 6 1228 Freescale Semiconductor...
Page 1440: ...FlexCAN Module MPC5644A Microcontroller Reference Manual Rev 6 1440 Freescale Semiconductor...