
Enhanced Queued Analog-to-Digital Converter (EQADC)
MPC5644A Microcontroller Reference Manual, Rev. 6
Freescale Semiconductor
1149
25.6.10.1 Input / Output signals description
The information content of the input and the output data buses from/to the companion modules are
described in
. The input data format is used in the Read cycle and corresponds to the data
supplied by some companion module. The output data format is used in the Write cycle of this interface
block and contains information / controls to some companion module.
Figure 25-90. PSI Input and Output Data Buses Content
FLUSH — Master block Flush request/control bit
The FLUSH signal is used to request a Flush flow in the slave block. More details is presented in item
Section , Conversion Command Format for Alternate Configurations
1 = Flush request
0 = No flush request.
CTRL[0:1] — Control bits
describes the CTRL[0:1] field functions. This field is used for the control of the
companion module.
MESSAGE_TAG[0:3] — Message tag bits field
Read (Input) / Write (Output) Data Buses Content
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
R
0
0
0
0
TAG
[0:3]
W
FLU
SH
CTRL
[0:1]
MESSAGE_TAG
[0:3]
RESET:
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
R
RESULT_DATA
[0:15]
W
ADC_CONV_RESULT
[0:15]
RESET:
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
= Unimplemented or Reserved
Table 25-74. CTRL[0:1] field description
CTRL[0:1]
Description
00
INH_RET or PREFILL - This mode indicates that the companion module should not
send back some RESULT_DATA corresponding to the accompanying
ADC_CONV_RESULT data.
When the slave module is the Decimation Filter, this control enables the PREFILL
filter mode.
01
CONVERSION RESULT - It indicates that the ADC_CONV_RESULT field should be
treated as a valid sample data. This control mode is useful to Decimation Filter to put
the filter em normal mode instead of prefill mode.
10
TIME STAMP o REGISTER READ - A time stamp indicates that the
ADC_CONV_RESULT field should follow a bypass flow in the companion module,
returning back to the EQADC without any modification.
11
reserved
Summary of Contents for MPC5644A
Page 2: ...MPC5644A Microcontroller Reference Manual Rev 6 2 Freescale Semiconductor...
Page 24: ...MPC5644A Microcontroller Reference Manual Rev 6 24 Freescale Semiconductor...
Page 26: ...MPC5644A Microcontroller Reference Manual Rev 6 26 Freescale Semiconductor...
Page 52: ...Introduction MPC5644A Microcontroller Reference Manual Rev 6 52 Freescale Semiconductor...
Page 56: ...Memory Map MPC5644A Microcontroller Reference Manual Rev 6 56 Freescale Semiconductor...
Page 1228: ...Decimation Filter MPC5644A Microcontroller Reference Manual Rev 6 1228 Freescale Semiconductor...
Page 1440: ...FlexCAN Module MPC5644A Microcontroller Reference Manual Rev 6 1440 Freescale Semiconductor...