Enhanced Queued Analog-to-Digital Converter (EQADC)
MPC5644A Microcontroller Reference Manual, Rev. 6
1112
Freescale Semiconductor
For CFIFOs configured for level-trigger mode, a trigger overrun event is only detected when the gate
closes and opens during a single serial command transmission as shown in
.
Figure 25-68. Trigger Overrun on Level-Trigger Mode CFIFOs
NOTE
The trigger overrun flag will not set for CFIFOs configured for software
trigger mode.
25.6.4.7.5
Command Sequence Non-Coherency Detection
The EQADC provides a mechanism to indicate if a command sequence has been completely executed
without interruptions. A command sequence is defined as a group of consecutive commands bound for the
same CBuffer and it is expected to be executed without interruptions. A command sequence is coherent if
its commands are executed in order without interruptions. Since commands are stored in the CBuffers
before being executed in the EQADC, a command sequence is coherent if, while it is transferring
commands to a CBuffer, the buffer is only fed with commands from that sequence without ever becoming
empty.
A command sequence starts when:
•
a CFIFO in TRIGGERED state transfers its first command to CBuffer.
•
the CFIFO is constantly transferring commands and the previous command sequence ended.
•
the CFIFO resumes command transfers after being interrupted.
And a command sequence ends when:
•
an asserted EOQ bit is detected on the last transferred command.
•
CFIFO is in edge-trigger mode and asserted PAUSE bit is detected on the last transferred
command.
•
the CBuffer to which the next command is bound is different from the one to which the last
command was transferred.
Command Transmission
through EQADC SSI
Assumptions:
Low Active Level Trigger
CFIFO Status
TORF
Command 1
Null Message
Command 2
TRIGGERED
WFT
TRIGGERED WFT
TRIGGERED
If gate closes during a command transmission it is only recognized
when the transmission ends.
1) CFIFO programmed to “continuous-scan low level gated external trigger mode”
2) Command 2 has its ABORT_ST bit negated.
WFT= WAITING FOR TRIGGER
3) There are no other CFIFOs using the serial interface.
Summary of Contents for MPC5644A
Page 2: ...MPC5644A Microcontroller Reference Manual Rev 6 2 Freescale Semiconductor...
Page 24: ...MPC5644A Microcontroller Reference Manual Rev 6 24 Freescale Semiconductor...
Page 26: ...MPC5644A Microcontroller Reference Manual Rev 6 26 Freescale Semiconductor...
Page 52: ...Introduction MPC5644A Microcontroller Reference Manual Rev 6 52 Freescale Semiconductor...
Page 56: ...Memory Map MPC5644A Microcontroller Reference Manual Rev 6 56 Freescale Semiconductor...
Page 1228: ...Decimation Filter MPC5644A Microcontroller Reference Manual Rev 6 1228 Freescale Semiconductor...
Page 1440: ...FlexCAN Module MPC5644A Microcontroller Reference Manual Rev 6 1440 Freescale Semiconductor...