ATM-INTF (TN2305/6)
Issue 4 May 2002
10-213
555-233-123
Control Channel Loop-Around Test (#52)
This test is non-destructive. This test queries the circuit pack for its circuit pack
code and vintage and verifies its records.
Table 10-78. TEST #52 Control Channel Loop-Around Test
Error
Code
Test
Result
Description/Recommendation
2000
ABORT
Response to the test request was not received within the
allowable time period.
2100
ABORT
System resources required to run this test are not available.
2500
ABORT
Internal system error
1. Retry the command at 1-minute intervals for a maximum of 5
times.
FAIL
The circuit pack failed to return the circuit pack code or vintage.
1. Retry the command a few times for a maximum of 5 times.
2. If the problem continues to fail, reset the circuit pack.
3. Retry the command a few times for a maximum of 5 times.
PASS
Communication with this circuit pack is successful.
Any
NO
BOARD
This is normal if the test is being done when:
■
the board is not physically in the system.
■
the system is booting up.
Otherwise, there is some inconsistency in the data kept in the
system.
1. Verify that the board is physically in the system.
2. Verify that the system is not in the process of booting up.
3. Retry the command at 1-minute intervals for a maximum of 5
times.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...