PKT-CTRL (Packet Control Circuit Pack)
Issue 4 May 2002
10-1281
555-233-123
1141
ABORT
The Packet Control circuit pack is not operational.
NOTE:
A busied-out Packet Control circuit pack can still be
operational.
1. Determine if the Packet Control circuit pack has an active
major alarm (via the display alarm command). If it does,
then follow the recommended repair procedures to retire
the alarm. Once the alarm is retired, the original
command can be retried.
2. If the Packet Control circuit pack does not have an active
major alarm, then wait one minute and retry the original
command. If the Error Code 1141 is observed again, go to
the next step.
3. If the Packet Control is not currently busied-out and is on
the active SPE, issue the busyout packet-control C
command. Issue the reset packet-control C command. If
the reset command fails, follow the recommended repair
procedures for Test #586. If the reset command passes,
issue the release packet-control C command (if the
Packet Control circuit pack is on the active SPE), and
then reissue the original command.
1143
ABORT
The test should not be run in a High or Critical Reliability
system.
1. No action is required since the parity circuitry is not used
to monitor the Packet Bus in a High or Critical Reliability
system.
2100
ABORT
Was unable to allocate necessary resources.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2500
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
Table 10-480.
TEST #584 Packet Control Parity Circuitry Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...