SW-CTL (Switch Control)
Issue 4 May 2002
10-1585
555-233-123
Table 10-587.
TEST #325 Switch Control Destructive EPN
Maintenance Board Interface Test
Error
Code
Test
Result
Description/Recommendation
1005
ABORT
The system does not contain an EPN so this test is not
executed.
32500
ABORT
Test disabled through software patch.
2013
32511
ABORT
Could not allocate the system resources to run for this test.
2012
32513
32514
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
1029
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT
Refer to STBY-SPE for a description of these error codes.
32515
FAIL
This failure indicates that communications with the
Maintenance circuit pack in the EPN is probably not possible.
The EPN management terminal may not be usable.
1. Run the Long Test Sequence several times to make sure
the error is occurring consistently. Remember the Long
Test Sequence is destructive. Placing and receiving
calls is affected for several seconds.
2. Replace the NetPkt or Netcon circuit pack.
PASS
The EPN Maintenance circuit pack interface between the
processor and the Switch Control is working correctly.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...