Maintenance Object Repair Procedures
555-233-123
10-530
Issue 4 May 2002
Port Audit and Update Test (#36)
This test sends port level translation data from the switch processor to the DS1
Interface circuit pack to assure that the trunk’s translation is correct. Translation
updates include the following data: trunk type (in/out), dial type, timing
parameters, and signaling bits enabled. The port audit operation verifies the
consistency of the current state of the trunk as kept in the DS1 Interface circuit
pack and in the switch software.
Table 10-195.
TEST #36 Port Audit and Update Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Internal System Error.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1000
ABORT
The port may be busy with a valid call. Issue the display port
PCSSpp command to determine the trunk group/member
number of the port. Use the status trunk command to
determine the service state of the port. If the service state
indicates that the port is in use, then the port is unavailable for
certain tests. You must wait until the port is idle before
retesting.
1. If the port status is active but the port is not in use (no
calls), check the error log for error type 1025 (see the
Error Log table for a description of this error and required
actions). The port may be locked up.
2. If the port status is idle, retry the command at 1 minute
intervals for a maximum of 5 times.
1006
ABORT
The test was aborted because the trunk is out of service.
1. Use the status trunk command to verify that the trunk is
out of service.
2. If the trunk is out of service, determine why.
3. If it is OK to put the trunk back in service, issue the
release trunk command to put the trunk back in service,
and then retry the test.
2000
ABORT
Response to the test was not received within the allowable
time period.
2100
ABORT
Could not allocate resources to run this test.
1. Retry the command at 1 minute intervals for a maximum of
5 times.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...