PI-BD (Processor Interface Circuit Pack)
Issue 4 May 2002
10-1225
555-233-123
!
WARNING:
The “test interface long” command resets the PI-BD and cause all ISDN-PRI
and BX.25 links to come down.
Notes:
a. Indicates the circuit pack totally stopped functioning or it was physically
removed from the system.
NOTE:
The alarm is logged about 11 minutes after the circuit pack has been
removed and/or SAKI Test (#53) fails.
If the circuit pack is not in the system, insert a circuit pack (in the same slot
as the error indicates) to resolve this error. Or, if the circuit pack is in the
system and the red LED is on, then replace the circuit pack.
!
CAUTION:
Reseating the circuit pack may cause a system restart if the circuit
pack is located on an Active SPE complex.
If this is a Duplicated Option system, verify that there is an equal number of
Processor Interface circuit packs in each SPE complex. If there is not an
equal number of Processor Interface circuit packs, this condition could
cause alarms on the STBY-SPE, DUPINT, SHDW-CIR, as well as the
PI-BD.
1025 (i)
4363
NPE Audit Test (#50)
test interface PCS sh
1538 (j)
Any
None
MINOR
ON
3585 (d)
Any
None Test (#423)
MAJOR
ON
reset interface PCS l
3840 (i)
Any
None
3841
Any
Standby PI Circuit Pack
Test (#423)
MAJOR
ON
test interface PCS sh
3999(k)
Any
None
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Table 10-458.
PI-BD Error Log Entries — Continued
Error
Code
Aux
Data
Associated Test
Alarm
Level
On/
Off
Board
Test to Clear Value
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...